Script
This script can be used to inventory servers or workstations. You can easily adjust to use it within the login script instead of running interactive. It gathers information such as hardware details or environment (registry, IP address, etc)
On error Resume next
'Collecting IP Address
Function IP(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set IPConfigSet = objWMIService.ExecQuery _
("Select * from Win32_NetworkAdapterConfiguration Where IPEnabled=TRUE")
For Each IPConfig in IPConfigSet
If Not IsNull(IPConfig.IPAddress) Then
For i=LBound(IPConfig.IPAddress) to UBound(IPConfig.IPAddress)
If Left(IPConfig.IPAddress(i),3) = "10." Then
'WScript.Echo "IP: " & IPConfig.IPAddress(i)
strResult = IPConfig.IPAddress(i)
End If
Next
End If
Next
IP = strResult
End Function
'Collecting MAC Address
Function MacAddress(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set IPConfigSet = objWMIService.ExecQuery _
("Select * from Win32_NetworkAdapterConfiguration Where IPEnabled=TRUE")
For Each IPConfig in IPConfigSet
If Not IsNull(IPConfig.IPAddress) Then
For i=LBound(IPConfig.IPAddress) to UBound(IPConfig.IPAddress)
If Left(IPConfig.IPAddress(i),3) = "10." Then
'WScript.Echo "MAC: " & IPConfig.MACAddress(i)
strResult = IPConfig.MACAddress(i)
End If
Next
End If
Next
MacAddress = strResult
End Function
'Collecting Hostname
Function Hostname(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_ComputerSystem", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems
'WScript.Echo "Hostname: " & objItem.Name
strResult = objItem.Name
Next
Hostname = strResult
End Function
'Collecting logged on User
Function LoggedUser(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_ComputerSystem", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems
'WScript.Echo "UserName: " & objItem.UserName
strResult = objItem.UserName
Next
LoggedUser = strResult
End Function
'Collecting Manufacturer
Function Manufacturer(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_BaseBoard")
For Each objItem In colItems
'WScript.Echo "Manufacturer: " & objItem.Manufacturer
strResult = objItem.Manufacturer
Next
Manufacturer = strResult
End Function
'Collecting Model
Function Model(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_ComputerSystemProduct", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems
'WScript.Echo "Model: " & objItem.Name
strResult = objItem.Name
Next
Model = strResult
End Function
'Collecting Free Memory
Function MemFree(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_OperatingSystem", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems
strResult = objItem.FreePhysicalMemory
Next
MemFree = strResult
End Function
'Collecting Installed Memory
Function Memory(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_PhysicalMemory", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
strResult = 0
For Each objItem In colItems
'WScript.Echo "Memory Capacity: " & objItem.Capacity
strResult = strResult + objItem.Capacity
Next
Memory = strResult/1024/1024
End Function
'Collecting Hard Drive size
Function HDD(strComputer)
Const wbemFlagReturnImmediately = &h10
Const wbemFlagForwardOnly = &h20
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_DiskDrive", "WQL", _
wbemFlagReturnImmediately + wbemFlagForwardOnly)
For Each objItem In colItems
'WScript.Echo "HDD Size: " & objItem.Size
strResult = objItem.Size
Next
HDD = CInt(strResult/1024/1024/1024)
End Function
'Collecting Processor
Function Processor(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_Processor")
For Each objItem in colItems
'Wscript.Echo "Processor: " & objItem.Name
strResult = objItem.Name
Next
Processor = strResult
End Function
'Collecting Clock Speed (MHz)
Function Clock(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_Processor")
For Each objItem in colItems
'Wscript.Echo "Clock Speed: " & objItem.CurrentClockSpeed
strResult = objItem.CurrentClockSpeed
Next
Clock = strResult
End Function
'Collecting Operating System
Function OperSystem(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery ("Select * from Win32_OperatingSystem")
For Each objItem in colItems
'WScript.Echo "Operational System: " & objItem.Caption
strResult = objItem.Caption
Next
OperSystem = strResult
End Function
'Collecting Service Pack Version
Function ServicePack(strComputer)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colOperatingSystems = objWMIService.ExecQuery ("Select * from Win32_OperatingSystem")
For Each objOperatingSystem in colOperatingSystems
strResult = objOperatingSystem.ServicePackMajorVersion _
& "." & objOperatingSystem.ServicePackMinorVersion
Next
ServicePack = strResult
End Function
'Collecting custom Registry Key
Function RegKey(strComputer)
strResult = "0"
'Set WshShell = WScript.CreateObject("WScript.Shell")
'strResult = WshShell.RegWrite("HKCU\Software\ACME\FortuneTeller\", 1, "REG_BINARY")
'strResult = WshShell.RegWrite("HKCU\Software\ACME\FortuneTeller\MindReader", "Goocher!", "REG_SZ")
'strResult = WshShell.RegRead("HKLM\SOFTWARE\ComputerAssociates\eTrustAntivirus\CurrentVersion")
const HKEY_LOCAL_MACHINE = &H80000002, HKEY_CURRENT_USER = &H80000001
Set objReg=GetObject("winmgmts:{impersonationLevel=impersonate}!\\" & strComputer & "\root\default:StdRegProv")
strKeyPath = "SOFTWARE\Manufacturer\Software"
strValueName = "value"
objReg.GetStringValue HKEY_LOCAL_MACHINE,strKeyPath,strValueName,strResult
RegKey = strResult
End Function
'Collecting environment variable
Function VarLOGONSERVER(strComputer)
strResult = "0"
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_Environment")
For Each objItem in colItems
If objItem.Name = "LOGONSERVER" Then
strResult = objItem.VariableValue
End If
Next
VarLOGONSERVER = strResult
End Function
'Collecting amount of Physical Cores
Function PhysicalCores(strComputer)
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_Processor", "WQL")
For Each objItem in colItems
strResult = objItem.NumberOfCores
Next
PhysicalCores = strResult
End Function
'Collecting logical Processors
Function Processors(strComputer)
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\CIMV2")
Set colItems = objWMIService.ExecQuery("SELECT * FROM Win32_Processor", "WQL")
For Each objItem in colItems
strResult = objItem.NumberOfLogicalProcessors
Next
Processors = strResult
End Function
'************ Begin Code ************
Set objFSO = CreateObject("Scripting.FileSystemObject")
Const ForReading = 1, ForWriting = 2, ForAppending = 8
Const AllwaysCreate = 1
'Initializing report file
strFileRpt = InputBox("Select report file", "Inventory", "C:\report.txt")
If (strFileRpt <> "") then
Set objFileRpt = objFSO.OpenTextFile(strFileRpt, ForAppending, AllwaysCreate)
'Setting Header
objFileRpt.WriteLine("Hostname;Manufacturer;Model;Memory (MB);Free Memory (KB);HDD (GB);Processor;Clock (MHz);Operational System;ServicePack;IP;PhysicalCores;Processors")
End if
'Getting hostname to connect as CLI parameter
'Set objHosts=WScript.Arguments
'If objHosts.count > 0 then
' strComputer=objHosts(0)
'Else
' strComputer="."
'End If
'Getting hostnames from a text file
strHosts = InputBox("Select hosts file", "Inventory", "C:\hosts.txt")
Set objHosts = objFSO.OpenTextFile(strHosts, ForReading)
Do Until objHosts.AtEndOfStream
strComputer = objHosts.Readline
WScript.Echo
WScript.Echo "=========================================="
WScript.Echo "Hostname: " & strComputer
WScript.Echo "=========================================="
'Starting collecting inventory for current host
objFileRpt.WriteLine(Hostname(strComputer) & ";" & Manufacturer(strComputer) & ";" & Model(strComputer) & ";" & Memory(strComputer) & ";" & MemFree(strComputer) & ";" & HDD(strComputer) & ";" & Processor(strComputer) & ";" & Clock(strComputer) & ";" & OperSystem(strComputer) & ";" & ServicePack(strComputer) & ";" & IP(strComputer) & ";" & PhysicalCores(strComputer) & ";" & Processors(strComputer) & ";")
Loop
objFileRpt.Close
objHosts.Close