Difference between revisions of "Enabling SNMP/email alerts"
Line 63: | Line 63: | ||
To restart the alertd process, type the following command: | To restart the alertd process, type the following command: | ||
tmsh restart /sys service alertd | tmsh restart /sys service alertd | ||
+ | |||
+ | *[https://support.f5.com/kb/en-us/products/big-ip-afm/manuals/product/network-firewall-policies-implementations-12-1-0/18.html SNMP Traps] |
Latest revision as of 01:32, 11 December 2018
Log in to the Traffic Management Shell (tmsh) by typing the following command:
tmsh
To configure the system to send locally generated email messages, use the following command syntax:
modify /sys outbound-smtp mailhub <mail_server>:<port>
To save the configuration, type the following command:
save /sys config
Optional: If the SMTP mail host supports Secure Sockets Layer (SSL)/TLS authentication but does not establish a secure connection automatically, you must add the following four additional parameters into the /etc/ssmtp/ssmtp.conf configuration file:
UseSTARTTLS=yes UseTLS=yes AuthUser=<SMTP-Account-Username> AuthPass=<SMTP-Account-Password>
Verify that ssmtp is configured properly and can send an email message:
echo "ssmtp test mail" | mail -vs "Test email" [email protected]
To modify the permissions on the user_alert.conf file to include write access, type the following command:
chmod 644 /config/user_alert.conf
alert BIGIP_SHELL_BP_CONFIGURATION_LOADED { snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.28"; email toaddress="[email protected]" fromaddress="root" body="New configuration loaded" } alert BIGIP_MCPD_MCPDERR_POOL_MEMBER_MON_DOWN "Pool (.*?) member (.*?):(.*?) monitor status down." { snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.10"; lcdwarn description="Node down" priority="1" email toaddress="[email protected]" fromaddress="root" body="A pool member went down" } alert BIGIP_MCPD_MCPDERR_POOL_MEMBER_MON_UP "Pool (.*?) member (.*?):(.*?) monitor status up." { snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.11" email toaddress="[email protected]" fromaddress="root" body="A pool member came back up" } alert BIGIP_MCPD_MCPDERR_NODE_ADDRESS_MON_DOWN "Node (.*?) monitor status down." { snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.12"; lcdwarn description="Node address down" priority="1" email toaddress="[email protected]" fromaddress="root" body="A node went down" } alert BIGIP_MCPD_MCPDERR_NODE_ADDRESS_MON_UP "Node (.*?) monitor status up." { snmptrap OID=".1.3.6.1.4.1.3375.2.4.0.13" email toaddress="[email protected]" fromaddress="root" body="A node came up" }
To restore the permissions on the user_alert.conf file, type the following command:
chmod 444 /config/user_alert.conf
To restart the alertd process, type the following command:
tmsh restart /sys service alertd